# CVE-2025-30645

## Summary

- **CVE ID:** CVE-2025-30645
- **Severity:** HIGH
- **CVSS Score:** 8.7 (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/AU:Y/R:A/V:C/RE:M/U:Green)
- **CWE:** CWE-476
- **Published:** Apr 9, 2025
- **Last Modified:** Mar 12, 2026

## Description

A NULL Pointer Dereference vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack (DS) Lite tunnel to crash the flowd process, resulting in a Denial of Service (DoS).  Continuous triggering of specific control traffic will create a sustained Denial of Service (DoS) condition.

On all SRX platforms, when specific, valid control traffic needs to be sent out of a DS-Lite tunnel, a segmentation fault occurs within the flowd process, resulting in a network outage until the flowd process restarts.

This issue affects Junos OS on SRX Series: 
  *  All versions before 21.2R3-S9, 
  *  from 21.4 before 21.4R3-S9, 
  *  from 22.2 before 22.2R3-S5, 
  *  from 22.4 before 22.4R3-S6, 
  *  from 23.2 before 23.2R2-S3, 
  *  from 23.4 before 23.4R2.

## Affected Products

- Juniper Networks — Junos OS (0)
- Juniper Networks — Junos OS (21.4)
- Juniper Networks — Junos OS (22.2)
- Juniper Networks — Junos OS (22.4)
- Juniper Networks — Junos OS (23.2)
- Juniper Networks — Junos OS (23.4)

## References

- [CNA](https://supportportal.juniper.net/JSA96455)

## Exploitation Prediction (EPSS)

- **EPSS Score:** 0.42%
- **EPSS Percentile:** 35.1

---